-
The statistical variability of globally averaged MODIS aerosol optical thickness at 0.55 μm (AOT) and top of atmosphere CERES cloud-free shortwave radiative effect (SWRE) is presented. Statistical variability is defined as the robustness of globally averaged statistics relative to data distribution. At the CERES footprint level, which we label "raw data", both the AOT and SWRE data derived from clear-sky CERES-SSF products show significant deviations from a normal distribution as evidenced by high skewness values. The spatial and temporal distribution of the data is also not uniform, with a greater concentration of data occurring in aerosol heavy-regions. As a result, globally averaged AOT and SWRE are overestimated when derived from raw data alone. To compensate, raw data are gridded into 2×2 degree grid-cells (called "gridded" data) to reduce the effect of spatial non-uniformity. However, the underlying non-normal distribution remains and manifests itself by increasing the uncertainty of grid-cell values. Globally averaged AOT and SWRE derived from a gridded dataset are substantially lower than those derived from raw data alone. The range of globally averaged AOT and SWRE values suggests that up to a 50% statistical variability exists, much of which is directly tied to how the data are manipulated prior to averaging. This variability increases when analyzing aerosol components (e.g. anthropogenic) since component AOT (and SWRE) may not exist at all locations were AOT is present. As a result, regions where a particular component AOT does not exist must either not be included in the global average or have data within these regions set to null values. However, each method produces significantly different results. The results of this work indicate simple mean and standard deviation statistics do not adequately describe global aerosol climate forcing data sets like the one used here. We demonstrate that placing raw observations on to a uniform grid is a necessary step before calculating global statistics. However, this by no means eliminates uncertainty in globally averaged AOT and SWRE values, while adding its own set of assumptions. When reporting any globally averaged statistic, it is important to report corresponding distribution and coverage information, in the form of skewness values, probability density functions, and spatial distribution plots, to help quantify its usefulness and robustness.
-
The innovations or observation minus forecast (O–F) residuals produced by a data assimilation system provide a convenient metric of evaluating global analyses. In this study, O–F statistics from the Global Ozone Assimilation Testing System (GOATS) are used to examine how ozone assimilation products and their associated O–F statistics depend on input data biases and ozone photochemistry parameterizations (OPP). All the GOATS results shown are based on a 6-h forecast and analysis cycle using observations from SBUV/2 (Solar Backscatter UltraViolet instrument-2) during September–October 2002. Results show that zonal mean ozone analyses are more independent of observation biases and drifts when using an OPP, while the mean ozone O–Fs are more sensitive to observation drifts when using an OPP. In addition, SD O–Fs (standard deviations) are reduced in the upper stratosphere when using an OPP due to a reduction of forecast model noise and to increased covariance between the forecast model and the observations. Experiments that changed the OPP reference state to match the observations by using an "adaptive" OPP scheme reduced the mean ozone O–Fs at the expense of zonal mean ozone analyses being more susceptible to data biases and drifts. Additional experiments showed that the upper boundary of the ozone DAS can affect the quality of the ozone analysis and therefore should be placed well above (at least a scale height) the region of interest.
-
Cloud condensation nucleus (CCN) experiments were carried out for malonic acid, succinic acid, oxalacetic acid, DL-malic acid, glutaric acid, DL-glutamic acid monohydrate, and adipic acid, using both water and methanol as atomization solvents, at three operating supersaturations (0.11%, 0.21%, and 0.32%) in the Caltech three-column CCN instrument (CCNC3). Predictions of CCN behavior for five of these compounds were made using the Aerosol Diameter Dependent Equilibrium Model (ADDEM). The experiments presented here expose important considerations associated with the laboratory measurement of the CCN behavior of organic compounds. Choice of atomization solvent results in significant differences in CCN activation for some of the compounds studied, which could result from residual solvent, particle morphology differences, and chemical reactions between the particle and gas phases. Also, significant changes in aerosol size distribution occurred after classification in a differential mobility analyzer (DMA) for malonic acid and glutaric acid, preventing confident interpretation of experimental data for these two compounds. Filter analysis of adipic acid atomized from methanol solution indicates that gas-particle phase reactions may have taken place after atomization and before methanol was removed from the sample gas stream. Careful consideration of these experimental issues is necessary for successful design and interpretation of laboratory CCN measurements.
-
The PM<sub>10</sub> mass concentration levels and inorganic chemical composition were determined on 12-h resolution sampling during August 2003 and March 2004, in the centre of Athens, Greece. The August 2003 campaign mean PM<sub>10</sub> mass concentration, obtained by Beta Attenuation at 5 m above ground in Athinas Street, was 56 μg m<sup>−3</sup> while the corresponding value for March 2004 was 92 μg m<sup>−3</sup>. In both campaigns the E.U. imposed daily limit of 50 μg m<sup>−3</sup> was exceeded on several days. During the March campaign, in Athinas Street, additionally obtained DSFU-PM<sub>10</sub> (PM<sub>10-2.5</sub>+PM<sub>2.5</sub>) gravimetric mass concentrations (mean: 121 μg m<sup>−3</sup>) in the "breathing zone", at 1.5 m above ground were significantly higher compared to the respective mean PM<sub>10</sub> mass concentrations obtained by the same method at 25 m above ground, in a second site (AEDA; mean: 86 μg m<sup>−3</sup>) also in the centre of the city. The above findings suggest that, for a realistic estimation of the exposure of citizens to particulate matter, PM<sub>10</sub> sampling in the "breathing zone" (1.5–3 m above ground) is necessary. Such data are presented for the first time for the centre of Athens. In both campaigns, calcium was found to be the predominant component of the coarse fraction while crust-related aluminosilicates and iron were the other major components. The above elements constitute the most important components of the fine fraction, together with the predominant sulphur. All toxic metals were found in concentrations below the established air quality limits, and most of them in lower concentrations compared to older studies. Lead in particular, appeared mostly in the fine fraction and in very low concentrations compared to studies dating more than a decade back. The predominant ions of the coarse fraction have been found to be Ca<sup>2+</sup>, NO<sub>3</sub><sup>−</sup>, Na<sup>+</sup> and Cl<sup>−</sup>, while SO<sub>4</sub><sup>2−</sup>, Ca<sup>2+</sup> and NH<sub>4</sub><sup>+</sup> were the major ionic components of the fine fraction. In the fine particles, a low molar ratio of NH<sub>4</sub><sup>+</sup>/SO<sub>4</sub><sup>2−</sup> indicated an ammonium-poor ambient air, and together with inter-ionic correlations suggested that atmospheric ammonia is the major neutralizing agent of sulfate, while being insufficient to neutralize it to full extend. The formation of NH<sub>4</sub>NO<sub>3</sub> is therefore not favored and additional contribution to the neutralization of acidity has been shown to be provided by Ca<sup>2+</sup> and Mg<sup>2+</sup>. In the coarse particle fraction, the predominantly abundant Ca<sup>2+</sup> has been found to correlate well with NO<sub>3</sub><sup>−</sup> and SO<sub>4</sub><sup>2−</sup>, indicating its role as important neutralizing agent in this particle size range. The proximity of the location under study to the sea explains the important concentrations of salts with marine origin like NaCl and MgCl<sub>2</sub> that were found in the coarse fraction, while chloride depletion in the gaseous phase was found to be limited to the fine particulate fraction. Total analyzed inorganic mass (elemental+ionic) was found to be ranging between approximately 25–33% of the total coarse particle mass and 35–42% of the total fine particle mass.
-
We present the MESSy submodel MECCA-AERO, which simulates both aerosol and gas phase chemistry within one comprehensive mechanism. Including the aerosol phase into the chemistry mechanism increases the stiffness of the resulting set of differential equations. The numerical aspects of the approach followed in MECCA-AERO are presented. <br><br> MECCA-AERO requires input of an aerosol dynamical/microphysical model to provide the aerosol size and particle number information of the modes/bins for which the chemistry is explicitly calculated. Additional precautions are required to avoid the double counting of processes, especially for sulphate in the aerosol dynamical and the chemistry model. This coupling is explained in detail. <br><br> To illustrate the capabilities of the new aerosol submodel, examples for species usually treated in aerosol dynamical models are shown. The aerosol chemistry as provided by MECCA-AERO is very sumptuous and not readily applicable for long-term simulations, though it provides a reference to evaluate simplified approaches.
-
In early May 2006 a record high air pollution event was observed at Ny-Ålesund, Spitsbergen. An atypical weather pattern established a pathway for the rapid transport of biomass burning aerosols from agricultural fires in Eastern Europe to the Arctic. Atmospheric stability was such that the smoke was constrained to low levels, within 2 km of the surface during the transport. A description of this smoke event in terms of transport and main aerosol characteristics can be found in Stohl et al. (2007). This study puts emphasis on the radiative effect of the smoke. The aerosol number size distribution was characterised by lognormal parameters as having an accumulation mode centered around 165–185 nm and almost 1.6 for geometric standard deviation of the mode. Nucleation and small Aitken mode particles were almost completely suppressed within the smoke plume measured at Ny-Ålesund. Chemical and microphysical aerosol information obtained at Mt. Zeppelin (474 m a.s.l) was used to derive input parameters for a one-dimensional radiation transfer model to explore the radiative effects of the smoke. The daily mean heating rate calculated on 2 May 2006 for the average size distribution and measured chemical composition reached 0.55 K day<sup>−1</sup> at 0.5 km altitude for the assumed external mixture of the aerosols but showing much higher heating rates for an internal mixture (1.7 K day<sup>−1</sup>). In comparison a case study for March 2000 showed that the local climatic effects due to Arctic haze, using a regional climate model, HIRHAM, amounts to a maximum of 0.3 K day<sup>−1</sup> of heating at 2 km altitude (Treffeisen et al., 2005).
-
We have used the MODIS satellite data and two global aerosol models to investigate the relationships between aerosol optical depth (AOD) and cloud parameters that may be affected by the aerosol concentration. The relationships that are studied are mainly between AOD, on the one hand, and cloud cover, cloud liquid water path, and water vapour, on the other. Additionally, cloud droplet effective radius, cloud optical depth, cloud top pressure and aerosol Ångström exponent, have been analysed in a few cases. In the MODIS data we found, as in earlier studies, an enhancement in the cloud cover with increasing AOD. We find it likely that most of the strong increase in cloud cover with AOD, at least for AOD<0.2, is a result of aerosol-cloud interactions and a prolonged cloud lifetime. Large and mesoscale weather systems seem not to be a cause for the increase in cloud cover with AOD in this range. Sensitivity simulations show that when water uptake of the aerosols is not taken into account in the models the modelled cloud cover mostly decreases with AOD. Part of the relationship found in the MODIS data for AOD>0.2 can be explained by larger water uptake close to the clouds since relative humidity is higher in regions with higher cloud cover. The efficiency of the hygroscopic growth depends on aerosol type, the hygroscopic nature of the aerosol, the relative humidity, and to some extent the cloud screening. By analysing the Ångström exponent we find that the hygroscopic growth of the aerosol is not likely to be a main contributor to the cloud cover increase with AOD. Since the largest increase in cloud cover with AOD is for low AOD (~0.2) and thus also for low cloud cover, we argue that cloud contamination is not likely to play a large role. However, interpretation of the complex relationships between AOD and cloud parameters should be made with great care and further work is clearly needed.
-
The static (parallel-plate thermal-gradient) diffusion chamber (SDC) was one of the first instruments designed to measure cloud condensation nuclei (CCN) concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered supersaturation because of water vapor depletion with increasing particle concentration. The results obtained give a better understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail and can, in parts, be used for calibrations also for other types of CCN counters. <br><br> We conclude the following: 1) it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2) the number concentration calibration needs to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3) we observed no evidence that water vapor depletion lowered the supersaturation.
-
Among the major factors controlling ozone loss in the polar vortices in winter/spring is the kinetics of the ClO dimer catalytic cycle. Here, we propose a strategy to test and improve our understanding of these kinetics by comparing and combining information on the thermal equilibrium between ClO and Cl<sub>2</sub>O<sub>2</sub>, the rate of Cl<sub>2</sub>O<sub>2</sub> formation, and the Cl<sub>2</sub>O<sub>2</sub> photolysis rate from laboratory experiments, theoretical studies and field observations. Concordant with a number of earlier studies, we find considerable inconsistencies of some recent laboratory results with rate theory calculations and stratospheric observations of ClO and Cl<sub>2</sub>O<sub>2</sub>. The set of parameters for which we find the best overall consistency – namely the ClO/Cl<sub>2</sub>O<sub>2</sub> equilibrium constant suggested by Plenge et al. (2005), the Cl<sub>2</sub>O<sub>2</sub> recombination rate constant reported by Nickolaisen et al. (1994) and Cl<sub>2</sub>O<sub>2</sub> photolysis rates based on absorption cross sections in the range between the JPL 2006 assessment and the laboratory study by Burkholder et al. (1990) – is not congruent with the latest recommendations given by the JPL and IUPAC panels and does not represent the laboratory studies currently regarded as the most reliable experimental values. We show that the incorporation of new Pope et al. (2007) Cl<sub>2</sub>O<sub>2</sub> absorption cross sections into several models, combined with best estimates for other key parameters (based on either JPL and IUPAC evaluations or on our study), results in severe model underestimates of observed ClO and observed ozone loss rates. This finding suggests either the existence of an unknown process that drives the partitioning of ClO and Cl<sub>2</sub>O<sub>2</sub>, or else some unidentified problem with either the laboratory study or numerous measurements of atmospheric ClO. Our mechanistic understanding of the ClO/Cl<sub>2</sub>O<sub>2</sub> system is grossly lacking, with severe implications for our ability to simulate both present and future polar ozone depletion.
-
The Ozone Monitoring Instrument (OMI) is an imaging UV-VIS solar backscatter spectrometer and is designed and used primarily to retrieve trace gases like O<sub>3</sub> and NO<sub>2</sub> from the measured Earth reflectance spectrum in the UV-visible (270–500 nm). However, also aerosols are an important science target of OMI. The multi-wavelength algorithm is used to retrieve aerosol parameters from OMI spectral reflectance measurements in up to 20 wavelength bands. A Principal Component Analysis (PCA) is performed to quantify the information content of OMI reflectance measurements on aerosols and to assess the capability of the multi-wavelength algorithm to discern various aerosol types. This analysis is applied to synthetic reflectance measurements for desert dust, biomass burning aerosols, and weakly absorbing anthropogenic aerosol with a variety of aerosol optical thicknesses, aerosol layer altitudes, refractive indices and size distributions. The range of aerosol parameters considered covers the natural variability of tropospheric aerosols. This theoretical analysis is performed for a large number of scenarios with various geometries and surface albedo spectra for ocean, soil and vegetation. When the surface albedo spectrum is accurately known and clouds are absent, OMI reflectance measurements have 2 to 4 degrees of freedom that can be attributed to aerosol parameters. This information content depends on the observation geometry and the surface albedo spectrum. An additional wavelength band is evaluated, that comprises the O<sub>2</sub>-O<sub>2</sub> absorption band at a wavelength of 477 nm. It is found that this wavelength band adds significantly more information than any other individual band.