Skip to main content

Index Geophysics

InterServer Web Hosting and VPS
InterServer Web Hosting and VPS

Items

Advanced search
  • General information

  • South pacific regional conference on earthquake engineering, May 1979

  • In situ conditions affecting the ductility capacity of lightly reinforced concrete wall structures in the Canterbury earthquake sequence

    Following the 2010-2011 Canterbury (New Zealand) earthquake sequence, lightly reinforced wall structures in the Christchurch central business district were observed to form undesirable crack patterns in the plastic hinge region, while yield penetration either side of cracks and into development zones was less than predicted using empirical expressions. To some extent this structural behaviour was unexpected and has therefore demonstrated that there may be less confidence in the seismic performance of conventionally designed reinforced concrete (RC) structures than previously anticipated. This paper provides an observation-based comparison between the behaviour of RC structural components in laboratory testing and the unexpected structural behaviour of some case study buildings in Christchurch that formed concentrated inelastic deformations. The unexpected behaviour and poor overall seismic performance of ‘real’ buildings (compared to the behaviour of laboratory test specimens) was due to the localization of peak inelastic strains, which in some cases has arguably led to: (i) significantly less ductility capacity; (ii) less hysteretic energy dissipation; and (iii) the fracture of the longitudinal reinforcement. These observations have raised concerns about whether lightly reinforced wall structures can satisfy the performance objective of “Life Safety” at the Ultimate Limit State. The significance of these issues and potential consequences has prompted a review of potential problems with the testing conditions and procedures that are commonly used in seismic experimentations on RC structures. This paper attempts to revisit the principles of RC mechanics, in particular, the influence of loading history, concrete tensile strength, and the quantity of longitudinal reinforcement on the performance of real RC structures. Consideration of these issues in future research on the seismic performance of RC might improve the current confidence levels in newly designed conventional RC structures.
  • An inventory of unreinforced masonry churches in New Zealand

    Churches are an important part of New Zealand’s historical and architectural heritage. Various earthquakes around the world have highlighted the significant seismic vulnerability of religious buildings, with the extensive damage that occurred to stone and clay-brick unreinforced masonry churches after the 2010-2011 Canterbury earthquakes emphasising the necessity to better understand this structural type. Consequently, a country-wide inventory of unreinforced masonry churches is here identified. After a bibliographic and archival investigation, and a 10 000 km field trip, it is estimated that currently 297 unreinforced masonry churches are present throughout New Zealand, excluding 12 churches demolished in Christchurch because of heavy damage sustained during the Canterbury earthquake sequence. The compiled database includes general information about the buildings, their architectural features and structural characteristics, and any architectural and structural transformations that have occurred in the past. Statistics about the occurrence of each feature are provided and preliminary interpretations of their role on seismic vulnerability are discussed. The list of identified churches is reported in annexes, supporting their identification and providing their address.
  • Analytical simulation of seismic collapse of RC frame buildings

    Application of a fibre-element nonlinear modelling technique for seismic collapse capacity assessment of RC frame buildings in comparison with conventional lumped plasticity models is investigated in this paper. Constitutive material models of concrete and steel for fibre elements are adopted to enable simulation of the loss in vertical load carrying capacity of structural columns. Inclusion of the nonlinear second order P−Δ effects accelerated by degrading behaviour of steel and concrete materials in the fibre model allows prediction of the sidesway mode of collapse. The model is compared with nonlinear lumped plasticity models in which stiffness and strength degradation is replicated through degrading parameters in structural components. Static cyclic analyses of an example cantilever column and a portal frame indicate that the variation of axial loads in columns may result in accelerated degradation and failure of structural components which is not taken into account by lumped plasticity models. Moreover, incremental dynamic analysis of a ten-storey RC frame shows that the lumped plasticity model may overestimate building collapse capacity when vertical failure of structural components occurs prior to sidesway instability.
  • Soil profile characterisation of Christchurch Central Business District strong motion stations

    This paper presents an overview of the soil profile characteristics at strong motion station (SMS) locations in the Christchurch Central Business District (CBD) based on recently completed geotechnical site investigations. Given the variability of Christchurch soils, detailed investigations were needed in close vicinity to each SMS. In this regard, CPT, SPT and borehole data, and shear wave velocity (Vs) profiles from surface wave dispersion data in close vicinity to the SMSs have been used to develop detailed representative soil profiles at each site and to determine site classes according to the New Zealand standard NZS1170.5. A disparity between the NZS1170.5 site classes based on Vs and SPT N60 investigation techniques is highlighted, and additional studies are needed to harmonize site classification based on these techniques. The short period mode of vibration of soft deposits above gravels, which are found throughout Christchurch, are compared to the long period mode of vibration of the entire soil profile to bedrock. These two distinct modes of vibration require further investigation to determine their impact on the site response. According to current American and European approaches to seismic site classification, all SMSs were classified as problematic soil sites due to the presence of liquefiable strata, soils which are not directly accounted for by the NZS1170.5 approach.
  • Performance evaluation of CWH base isolated building during two major earthquakes in Christchurch

    The seismic performance and parameter identification of the base isolated Christchurch Women’s Hospital (CWH) building are investigated using the recorded seismic accelerations during the two large earthquakes in Christchurch. A four degrees of freedom shear model is applied to characterize the dynamic behaviour of the CWH building during these earthquakes. A modified Gauss-Newton method is employed to identify the equivalent stiffness and Rayleigh damping coefficients of the building. The identification method is first validated using a simulated example structure and finally applied to the CWH building using recorded measurements from the Mw 6.0 and Mw 5.8 Christchurch earthquakes on December 23, 2011. The estimated response and recorded response for both earthquakes are compared with the cross correlation coefficients and the mean absolute percentage errors reported. The results indicate that the dynamic behaviour of the superstructure and base isolator was essentially within elastic range and the proposed shear linear model is sufficient for the prediction of the structural response of the CWH Hospital during these events.
  • New Zealand contributions to the Global Earthquake Model’s Earthquake Consequences Database (GEMECD)

    The Global Earthquake Model’s (GEM) Earthquake Consequences Database (GEMECD) aims to develop, for the first time, a standardised framework for collecting and collating geocoded consequence data induced by primary and secondary seismic hazards to different types of buildings, critical facilities, infrastructure and population, and relate this data to estimated ground motion intensity via the USGS ShakeMap Atlas. New Zealand is a partner of the GEMECD consortium and to-date has contributed with 7 events to the database, of which 4 are localised in the South Pacific area (Newcastle 1989; Luzon 1990; South of Java 2006 and Samoa Islands 2009) and 3 are NZ-specific events (Edgecumbe 1987; Darfield 2010 and Christchurch 2011). This contribution to GEMECD represented a unique opportunity for collating, comparing and reviewing existing damage datasets and harmonising them into a common, openly accessible and standardised database, from where the seismic performance of New Zealand buildings can be comparatively assessed. This paper firstly provides an overview of the GEMECD database structure, including taxonomies and guidelines to collect and report on earthquake-induced consequence data. Secondly, the paper presents a summary of the studies implemented for the 7 events, with particular focus on the Darfield (2010) and Christchurch (2011) earthquakes. Finally, examples of specific outcomes and potentials for NZ from using and processing GEMECD are presented, including: 1) the rationale for adopting the GEM taxonomy in NZ and any need for introducing NZ-specific attributes; 2) a complete overview of the building typological distribution in the Christchurch CBD prior to the Canterbury earthquakes and 3) some initial correlations between the level and extent of earthquake-induced physical damage to buildings, building safety/accessibility issues and the induced human casualties.
  • Smart semi-active MR damper to control the structural response

    One advanced means of protecting structures against earthquake ground motions is the use of semi-active devices to customise and limit structural response. Thus, the design, modelling and analysis of different semi-active control devices have received increasing research attention. This study presents a method to determine optimal control forces for magneto-rheological (MR) dampers, using three algorithms: a discrete wavelet transform (DWT), a linear quadratic regulator (LQR), and a clipped-optimal control algorithm. DWT is used to obtain the local energy distribution of the motivation over the frequency bands to modify conventional LQR. The clipped-optimal control algorithm is used to get the MR damper control force to approach the desired optimal force obtained from modified LQR. A Bouc-Wen phenomenological model is utilized to capture the observed nonlinear behaviour of MR dampers. Time history analysis for a single degree of freedom (SDOF) with periods of T= 0.2-5.0 sec is utilized to compare the impact of using classic and modified LQR in controlling the MR damper force under 20 design level earthquakes of the SAC (SEAOC-ATC-CUREE) project. Performance is assessed by comparing the maximum displacement (Sd), total base shear (Fb) and the controller energy. This study shows the proposed modified LQR is more effective at reducing displacement response than conventional LQR. The modified LQR method reduces the median value of uncontrolled Sd by approximately 40% to 88%, over all periods to 5.0 seconds. Moreover, the modified LQR uses about 45% less energy than conventional LQR. Overall, these results indicate the robustness of the proposed method to mitigate structural response and damage using MR devices.
  • Measured response of instrumented buildings during the 2013 Cook Strait earthquake sequence

    With the recent high level of earthquake activity throughout New Zealand there is growing awareness of the need for quick and reliable determination of whether buildings are safe. In parallel, on-going advances in sensors and computing technology have resulted in the potential for new and innovative sensing systems which could change the way that civil infrastructure is monitored, controlled and maintained. Following the 21 July 2013, MW 6.5 Cook Strait earthquakes, seven buildings in the Wellington region were instrumented with low-cost accelerometers to record building response data sets during aftershock excitations. A summary of the data analyses and insightful information obtained through processing and interpretation of the raw data is presented. Key challenges and considerations of installing a permanent structural monitoring system into buildings in New Zealand are discussed. The goal was to relate building performance indicators to decision making processes regarding the safety and resilience of structures post-earthquake. The information obtained was sufficiently reliable and valuable to the decision making process and New Zealand can expect more permanently instrumented buildings in the future.